| Operating Voltage |
DC 24 V ±15%, 15 W |
| Operating Environment |
−10 °C to +45 °C; relative humidity max. 85% RH |
| Protection Class |
IP65 |
| Net Weight |
Approx. 1.5 kg |
| Mounting |
Panel mount; cut-out 191.5 × 137.5 mm (W × H) |
| Display and Operation |
7-inch color LCD touch screen; multilingual interface including Turkish, English and Chinese; external USB keyboard and mouse support |
| Analog Weighing Excitation |
DC 10 V / 250 mA |
| Analog Signal Input Range |
0–25 mV |
| A/D Performance |
24-bit Σ-Δ ADC; internal resolution 1/100,000; sampling frequency 200 Hz |
| Zero Drift |
±0.1 µV/°C RTI (relative to input) |
| Gain Drift |
±10 ppm/°C |
| Non-linearity |
0.01% FS |
| Digital Weighing Excitation |
DC 24 V / 300 mA |
| Digital Weighing Interface |
CAN Bus; connects to digital sensors or digital junction boxes. The second channel can optionally be converted to analog weighing. |
| Speed Sensor Excitation |
DC 12 V / 100 mA |
| Speed Signal Input Range |
0.5–3000 Hz speed-pulse input; active low (NPN) |
| Digital Inputs (DI) |
3 configurable normally open switch inputs; active low (NPN) |
| Digital Outputs (DO) |
4 configurable normally open relay outputs; AC 220 V / 1 A |
| High-speed Pulse Output |
1 totalized-weight output; DC 5–24 V / 100 mA |
| Analog Input (AI) |
1 optional flow-setpoint input; 4–20 mA; non-linearity 0.05% FS |
| Analog Outputs (AO) |
Up to 3 configurable 4–20 mA outputs (AO3 optional); non-linearity 0.05% FS |
| COM1 |
Optional RS232 / RS485 / RS422 / Profibus-DP / Ethernet module |
| COM2 |
RS232 |
| Protocol |
Supports multiple communication protocols |
| USB |
For USB mouse connection, software upgrades and data backup to a USB drive |